[DOWNLOAD] Excel spreadsheet for evaluation of crack width according to Eurocode 2


Another addition for the Downloads section. In this post we’ll discuss about an Excel spreadsheet for the evaluation of the crack width in concrete structures. The inputs required are: INPUT Characteristic compressive cylinder strength fck 30 N/mm² Characteristic tensile strength of reinforcement fyk 500 N/mm² Base b 300 mm Height h 500 mm QP moment […]